An Uncommon Case Report of a Punctured SVC through a Chemo Port

Main Article Content

Dr. Vidhi Shah
Dr. Prriya Eshpuniyani
Dr. Shravan Shetty
Dr. Sagar Sharma
Dr. Jigar Zota
(Late)Dr. Dhairyasheel Savant
Dr. Sanjay Sharma
Dr. Ramakant Deshpande
Dr. Meghna Nadkarni
Dr. Sanjay Upadhaye
Dr. Shubham Gupta

Abstract

Chemo port implantation has enhanced the quality of life for cancer patients. Interventional radiologists or surgeons may implant chemo ports via the Internal Jugular Vein (IJV) or Subclavian Vein (SCV). A central catheter that is implanted into the central venous system is connected to a port chamber (subcutaneous) to form a venous port system. The catheter chamber's subcutaneous position enhances the patient quality of life and has a lower infection rate than non-totally implanted central venous devices. To avoid both immediate and long-term difficulties, a port system must be implanted, used, and cared for properly. Pneumothorax, hemothorax, thoracic duct damage, cardiac tamponade, venous malpositioning of the catheter, and perforation with arterial injury are the most frequent early complications (30 days). Infection, catheter thrombosis, vascular thrombosis and stenosis, catheter fracture with extravasation, or fracture with migration or catheter material embolization, are examples of delayed problems. To detect potential issues and plan therapeutic interventions, such as in the event of catheter migration, radiologic imaging has become more important in both intra-procedural assessment and postoperative follow-up.


 

Article Details

How to Cite
Dr. Vidhi Shah, Dr. Prriya Eshpuniyani, Dr. Shravan Shetty, Dr. Sagar Sharma, Dr. Jigar Zota, (Late)Dr. Dhairyasheel Savant, Dr. Sanjay Sharma, Dr. Ramakant Deshpande, Dr. Meghna Nadkarni, Dr. Sanjay Upadhaye, & Dr. Shubham Gupta. (2023). An Uncommon Case Report of a Punctured SVC through a Chemo Port. International Journal of Pharmaceutical and Bio Medical Science, 3(1), 07–10. https://doi.org/10.47191/ijpbms/v3-i1-02
Section
Articles
Author Biographies

Dr. Vidhi Shah, Consultant Breast OncoSurgeon Institute Asian Cancer Institute Cumballa Hill Hospital, Mumbai, Maharashtra

 

 

Dr. Prriya Eshpuniyani, Thoracic Surgeon, Institute Asian Cancer Institute Cumballa Hill Hospital, Mumbai, Maharashtra

 

 

Dr. Shravan Shetty, Surgical Oncologist, Institute Asian Cancer Institute Cumballa Hill Hospital, Mumbai, Maharashtra

 

 

Dr. Sagar Sharma , General Surgeon, Institute Asian Cancer Institute Cumballa Hill Hospital, Mumbai, Maharashtra

 

 

Dr. Jigar Zota , Consulting Radiologist, Institute Asian Cancer Institute Cumballa Hill Hospital, Mumbai, Maharashtra

 

 

(Late)Dr. Dhairyasheel Savant, Surgical Oncologist, Institute Asian Cancer Institute Cumballa Hill Hospital, Mumbai, Maharashtra

 

 

Dr. Sanjay Sharma, Surgical Oncologist, Institute Asian Cancer Institute Cumballa Hill Hospital, Mumbai, Maharashtra

 

 

Dr. Ramakant Deshpande, Surgical Oncologist, Institute Asian Cancer Institute Cumballa Hill Hospital, Mumbai, Maharashtra

 

 

Dr. Meghna Nadkarni, Anaesthesiologist, Institute Asian Cancer Institute Cumballa Hill Hospital, Mumbai, Maharashtra

 

 

Dr. Sanjay Upadhaye, Anaesthesiologist, Institute Asian Cancer Institute Cumballa Hill Hospital, Mumbai, Maharashtra

 

 

Dr. Shubham Gupta, Institute Asian Cancer Institute Cumballa Hill Hospital, Mumbai, Maharashtra

 

 

References

I. Madabhavi, I., Patel, A., Sarkar, M., Anand, A., Panchal, H., & Parikh, S. (2017). A Study of Use of "PORT" Catheter in Patients with Cancer: ASingle-Center Experience. Clinical Medicine Insights. Oncology, 11, 1179554917691031.

https://doi.org/10.1177/ 1179554917691031.

II. Aribas, B. K., Arda, K., Aribas, O., Ciledag, N., Yologlu, Z., Aktas, E., Seber, T., Kavak, S., Cosar, Y., Kaygusuz, H., & Tekin, E. (2012). Comparison of subcutaneous central venous port via jugular and subclavian access in 347 patients at a single center. Experimental and therapeutic medicine, 4(4), 675–680. https://doi.org/10.3892/ etm.2012.649

III. Plumhans C, Mahnken AH, Ocklenburg C, et al. Jugular versus subclavian totally implantable access ports: catheter position, complications and intrainterventional pain perception. Eur J Radiol. 2011;79:338–342.

IV. Walser EM. Venous access ports: indications, implantation technique, follow-up, and complications. Cardiovasc Intervent Radiol.

;35:751–764. doi: 10.1007/s00270-011-0271-2.

V. Teichgräber UK, Pfitzmann R, Hofmann HA (2011) Central venous port systems as an integral part of chemotherapy. Dtsch Arztebl Int 108:147–153

VI. F. J. Baumgartner, J. Rayhanabad, F. S. Bongard, J. C. Milliken, C. Donayre, and S. R. Klein, “Central venous injuries of the subclavian-jugular and innominate-caval confluences,” Texas Heart Institute Journal, vol. 26, no. 3, pp. 177–181, 1999.

VII. P. Duntley, J. Siever, M. L. Korwes, K. Harpel, and J. E. Heffner, “Vascular erosion by central venous catheters: clinical features and outcome,” Chest, vol. 101, no. 6, pp. 1633–1638, 1992.

VIII. A. Chabanier, F. Dany, P. Brutus, and H. Vergnoux, “Iatrogenic cardiac tamponade after central venous catheter,” Clinical Cardiology, vol. 11, no. 2, pp. 91–99, 1988.

IX. P. K. Li, C. W. Taylor III, and R. S. Chung, “Delayed hydrothorax: a complication of central venous catheterization,” Surgical Rounds, vol. 20, pp. 462–468, 1997

X. P. Gupta, S. Guleria, and S. Sharma, “Mediastinal haematoma: a rare complication following insertion of central venous catheter,” The Indian Journal of Chest Diseases & Allied Sciences, vol. 53, no. 4, pp. 225–228, 2011.

XI. ] N. Arik, T. Akpolat, F. Demirkan et al., “Mediastinal hematoma: a rare complication of subclavian catheterization for hemodialysis,” Nephron, vol. 63, no. 3, p. 354, 1993.

XII. M. Naguib, H. Farag, and R. N. Joshi, “Bilateral hydrothorax and hydromediastinum after a subclavian line insertion,” Canadian Anaesthetists Society Journal, vol. 32, no. 4, pp. 412–414, 1985.

XIII. Tocino IM, Watanabe A. Impending catheter perforation of superior vena cava: radiographic recognition. AJRAm J Roentgenol 1986; 146:487–90.

XIV. Duntley P, Siever J, Korwes ML, Harpel K, Heffner JE. Vascular erosions by central venous catheters. Clinicalfeatures and outcome. Chest 1992; 101: 1633–38